jksubsea

DIVING EQUIPMENTS

Hyperbaric Fire Extinguisher

J. K. Subsea Engineering Pvt. Ltd. is a trusted hyperbaric fire extinguisher manufacturer and supplier, building the Hyperbaric Fire Extinguisher, Model No. JK-HEX-6.8L, a non toxic foam extinguisher for the closed, pressurised space inside a diving chamber. A fire in a chamber leaves little room for error, because the people inside cannot walk away from it. Our extinguisher uses a non toxic foam agent for class A and B fires and electrical fires up to 24 volts, in a 6.8 litre cylinder charged with a fire cartridge. It is designed in line with IMCA D018 and IMCA D040, and it is the same unit we fit inside our air decompression chambers.

DIVING EQUIPMENTS

Hyperbaric Fire Extinguisher

J. K. Subsea Engineering Pvt. Ltd. is a trusted hyperbaric fire extinguisher manufacturer and supplier, building the Hyperbaric Fire Extinguisher, Model No. JK-HEX-6.8L, a non toxic foam extinguisher for the closed, pressurised space inside a diving chamber. A fire in a chamber leaves little room for error, because the people inside cannot walk away from it. Our extinguisher uses a non toxic foam agent for class A and B fires and electrical fires up to 24 volts, in a 6.8 litre cylinder charged with a fire cartridge. It is designed in line with IMCA D018 and IMCA D040, and it is the same unit we fit inside our air decompression chambers.

What is a Hyperbaric Fire Extinguisher?

A hyperbaric fire extinguisher is a fire suppression device made for use inside a pressurised chamber, such as a diving decompression chamber. Inside a chamber, the air is under pressure, the space is small, and the occupants breathe the same air they would be fighting a fire in. An extinguisher fitted there has to work under that pressure and leave the air safe to breathe. Ours uses a non toxic foam, which smothers fires on fabric and liquids and on low voltage electrical equipment. It is held upright and discharged in a controlled way, so the operator can aim the foam at the base of the fire. It is applicable for single lock recompression chambers, twin lock decompression chambers, and hyperbaric oxygen therapy chambers.

Key Features of the Hyperbaric Fire Extinguisher

Our hyperbaric chamber fire extinguisher, also used as a decompression chamber fire extinguisher, is built for fire safety in closed pressurised spaces.

  • Non Toxic Foam Agent: The foam is safe to use in a closed chamber where people breathe the air.
  • Electrical Fires Up to 24 Volts: Covers low voltage electrical fires, such as chamber lighting and panel equipment.
  • 6.8 Litre Cylinder: A compact size that fits inside a chamber compartment.
  • Wide Temperature Range: Rated from -15 C to 50 C.
  • IMCA Guideline Design: Designed in line with IMCA D018 and D040.
  • Class A and B Fire Rating: Works on fires in fabric and liquids.
  • Controlled Discharge: Used upright, so the operator can control where the foam goes.
  • Fire Cartridge Charging: Charged with a fire cartridge.
  • Simple Operation: Pull the pin, aim at the base of the fire, and squeeze the lever.

Maintenance of the Hyperbaric Fire Extinguisher

Have the extinguisher checked at least once a year, or sooner if an inspection shows the need. The check is a thorough one, to confirm the unit will work safely when needed. It can also show that the cylinder needs hydrostatic testing. A yearly check covers these points:

Clean off dirt and grease, and keep solvents away from the pressure gauge.

Weigh the extinguisher and compare it with the weight printed on the nameplate.

Inspect the pressure gauge, the foot stand, and the discharge lever for damage, dirt, or corrosion.

Remove the hose assembly and check it for damage. Check the air pressurising valve as well.

Look for damaged, missing, or substitute parts.

Check the date of manufacture on the hanger loop or nameplate.

Break the seal and check that the ring pin moves freely.

Refit the hose and nozzle, fit a new tamper seal, and record the service on the inspection tag.

Hang the extinguisher back on its wall bracket.

Technical Specifications of the Hyperbaric Fire Extinguisher

Technical Specifications

Specification Detail
Product Type Hyperbaric Fire Extinguisher
Model No. JK-HEX-6.8L
Extinguishing Agent Foam, non toxic
Fire Class A and B
Temperature Rating -15 C to 50 C
Working Pressure 150 bar
Cylinder Test Pressure 250 bar
Cylinder Volume 6.8 litres
Charging Gas Fire cartridge
Operating Position Upright, controlled discharge
Design Guidelines IMCA D018 and D040
Technical Data Sheet: For full details, download the complete technical data sheet.

Certifications and Standards for the Hyperbaric Fire Extinguisher Manufacturer

Our hyperbaric fire extinguisher (Model No. JK-HEX-6.8L) is designed in line with IMCA D018, the code of practice for the initial and periodic examination, testing, and certification of diving plant and systems, and IMCA D040, the design guideline for mobile and portable surface supplied systems. J. K. Subsea is an IMCA member.

IMCA D018

Certified

IMCA D040

Certified

Why Choose J. K. Subsea Engineering as Your Hyperbaric Fire Extinguisher Manufacturer

J. K. Subsea Engineering Pvt. Ltd. is a trusted hyperbaric fire extinguisher manufacturer and supplier, building safety equipment for commercial diving chambers.

Made for Chambers: Built for the closed, pressurised space inside a diving chamber.

Used in Our Own Chambers: The same unit we fit inside our air decompression chambers.

IMCA Member: Designed in line with IMCA D018 and D040.

Wide Product Range: We also manufacture and supply decompression chambers, hyperbaric lights and cameras, CO2 scrubbers, diving air panels, and diving fittings and valves.

Non Toxic Foam: Safe to use where people breathe the air.

Clear Service Guidance: A yearly check list comes with the data sheet.

Strong After-Sales Support: Ongoing technical support for offshore and subsea clients worldwide.

Frequently Asked Questions About the Hyperbaric Fire Extinguisher

What is a hyperbaric fire extinguisher?
A hyperbaric fire extinguisher is a fire extinguisher made for use inside a pressurised chamber, such as a diving decompression chamber. It uses a non toxic foam, so the people inside can use it without making the air unsafe to breathe.
Can I use a normal fire extinguisher inside a diving chamber?
No. A normal extinguisher is made for open spaces at normal air pressure, and some agents are not safe to breathe in a closed space. A hyperbaric extinguisher is made for the closed, pressurised space of a chamber and uses a non toxic foam.
Why does a decompression chamber need its own fire extinguisher?
The occupants cannot leave a chamber quickly, and a fire inside is a serious risk. Having an extinguisher inside lets the occupants or the attendant fight a fire at its start, while the chamber is still under pressure.
What type of agent does the J. K. Subsea hyperbaric fire extinguisher use?
It uses a non toxic foam. The foam is charged with a fire cartridge in a 5.9 litre cylinder.
What fires can it put out?
It is rated for class A and B fires, which means fires in fabric and liquids. It also covers electrical fires up to 24 volts.
Can it be used on high voltage electrical fires?
No. The electrical rating is up to 24 volts only.
How do you use a hyperbaric fire extinguisher?
Hold it upright so the discharge stays controlled. Pull out the safety pin, aim at the base of the fire, and squeeze the lever.
How often should a hyperbaric fire extinguisher be serviced?
At least once a year, or sooner if an inspection shows the need. The yearly check covers cleaning, a check for damaged or missing parts, weighing the unit against the nameplate weight, the pressure gauge, the ring pin, the discharge lever, and the hose. It can also show that the cylinder needs hydrostatic testing.
What temperature range is it rated for?
-15 C to 50 C.
What are the working pressure and test pressure of the cylinder?
The working pressure is 10 kg/cm2, and the cylinder test pressure is 15 kg/cm2.
Which standards is it designed to?
It is designed in line with IMCA D018 and IMCA D040. J. K. Subsea is an IMCA member.
Do your decompression chambers come with this extinguisher?
Yes. We fit a hyperbaric fire extinguisher inside our air decompression chambers, along with the other internal safety equipment.
Can I buy a replacement for an old extinguisher in my chamber?
Yes. Send us your chamber details and we will advise on a replacement, so you can keep your chamber’s fire protection up to date.
Who manufactures hyperbaric fire extinguishers in India?
J. K. Subsea Engineering Pvt. Ltd., based in Navi Mumbai, manufactures and supplies hyperbaric fire extinguishers for commercial diving and offshore operations in India and overseas.
How do I get a quote?
Send an enquiry with your chamber type and quantity, and our team will reply with pricing and delivery timelines.

Related Products

Get In Touch

Get Your Containerized Air Decompression Chamber Quote Today

Running an offshore diving spread and need a TPI approved decompression chamber with a dedicated control panel and full life support equipment? Talk to our team at J. K. Subsea Engineering Pvt. Ltd. for pricing on our Containerized Air Decompression Chamber with Control Panel (TPI), configuration options, and delivery timelines.